Features:
• Converts standard LED fixtures to emergency fixtures with 90 minutes of run time
• Provides up to 1300 lumens of illumination during a power outage
• UL1310 and CSA 22.2 listed for both factory or field installation
• Self-diagnostics capability eliminates labor intensive NFPA required monthly testing
• Compatible with LED products with 15 to 50 VDC operation
Specifications:
Illumination Time: Minimum 90 Minutes
Initial Light Output: 1300 lumens
Universal Input Voltage: 120-277 VAC, 50/60 Hz
Output Voltage: 15 - 52 VDC
Output Power: 10 W (Initial)
Test Switch / Charging Indicator Light: Test Button Indicator Light (TBIL)
Battery: High-Temperature, Maintenance-Free; Nickel-Cadmium Battery; 7- to 10-Year Life Expectancy
Recharge Time: 24 Hours
Charging Indicator Light: LED
Temperature Rating: Ambient: 0°C to 55°C (32°F to 131°F); Case: Tc (max): 65°C
Installation:
• The EBPLEDSD series does not affect normal fixture operation and may be used with either a switched or unswitched fixture.
• If a switched fixture is used, an unswitched hot lead must be connected to the emergency driver.
• The emergency driver must be fed from the same branch circuit as the AC driver.
• Installation is not recommended with fixtures where the ambient temperature may fall below 0° C.
Operation:
• During normal operation, the EBPLEDSD series constantly monitors battery voltage.
• When AC power fails, it immediately switches to the emergency mode, operating the LEDs at a reduced lumen output for a minimum of 90 minutes.
• When AC power is restored, the emergency driver automatically returns to the charging mode.
• During automated testing, the battery simulates an AC power failure, causing the emergency ballast to switch to emergency mode and conduct a discharge test to monitor battery voltage and LED's operation.
• If the EBPLEDSD detects a problem, the status indicator light flashes.
• When testing is complete, the EBPLEDSD returns to the charging mode.
• Automatically tests emergency lighting for 30 seconds once a month and 90 minutes once a year.
• Compatible with LED products with 15 to 50 VDC operation.
• Provides up to 1300 lumens of illumination during a power outage.
Application:
• UL Listed and can be used for normal and emergency options.
• Suitable for indoor and damp locations and for sealed & gasketed fixtures, including fixtures rated for wet locations.
• Not suitable for air handling heated air outlets and wet or hazardous locations.
For more information, Click Here - PDF
Please contact us for any additional options seen on specification sheet.
• Converts standard LED fixtures to emergency fixtures with 90 minutes of run time
• Provides up to 1300 lumens of illumination during a power outage
• UL1310 and CSA 22.2 listed for both factory or field installation
• Self-diagnostics capability eliminates labor intensive NFPA required monthly testing
• Compatible with LED products with 15 to 50 VDC operation
Specifications:
Illumination Time: Minimum 90 Minutes
Initial Light Output: 1300 lumens
Universal Input Voltage: 120-277 VAC, 50/60 Hz
Output Voltage: 15 - 52 VDC
Output Power: 10 W (Initial)
Test Switch / Charging Indicator Light: Test Button Indicator Light (TBIL)
Battery: High-Temperature, Maintenance-Free; Nickel-Cadmium Battery; 7- to 10-Year Life Expectancy
Recharge Time: 24 Hours
Charging Indicator Light: LED
Temperature Rating: Ambient: 0°C to 55°C (32°F to 131°F); Case: Tc (max): 65°C
Installation:
• The EBPLEDSD series does not affect normal fixture operation and may be used with either a switched or unswitched fixture.
• If a switched fixture is used, an unswitched hot lead must be connected to the emergency driver.
• The emergency driver must be fed from the same branch circuit as the AC driver.
• Installation is not recommended with fixtures where the ambient temperature may fall below 0° C.
Operation:
• During normal operation, the EBPLEDSD series constantly monitors battery voltage.
• When AC power fails, it immediately switches to the emergency mode, operating the LEDs at a reduced lumen output for a minimum of 90 minutes.
• When AC power is restored, the emergency driver automatically returns to the charging mode.
• During automated testing, the battery simulates an AC power failure, causing the emergency ballast to switch to emergency mode and conduct a discharge test to monitor battery voltage and LED's operation.
• If the EBPLEDSD detects a problem, the status indicator light flashes.
• When testing is complete, the EBPLEDSD returns to the charging mode.
• Automatically tests emergency lighting for 30 seconds once a month and 90 minutes once a year.
• Compatible with LED products with 15 to 50 VDC operation.
• Provides up to 1300 lumens of illumination during a power outage.
Application:
• UL Listed and can be used for normal and emergency options.
• Suitable for indoor and damp locations and for sealed & gasketed fixtures, including fixtures rated for wet locations.
• Not suitable for air handling heated air outlets and wet or hazardous locations.
For more information, Click Here - PDF
Please contact us for any additional options seen on specification sheet.