Application
• Residential driveway, sidewalk, access ramp, underground parking ramp, boarding platforms for animals
Construction
• Series heating cable set, twin conductor type
• Heating cable held as a mat at regular 3" (76 mm) spacing with flexible strips
• Fluoropolymer/XLPE resistance wire insulation 0.019" (0.5 mm) thick
• Copper shielding (0.823 sq. mm), serves as ground
• Polyolefin (EPR) outer sheath insulation 0.08" (2 mm) thick
Dimensions
• 24" (610 mm) wide
Cold lead
• 50' (15 m) long
• 12 AWG or 14 AWG (according to maximum allowable load)
• PVC outer sheath insulation 0.03" (0.76 mm) thick
• 3/8" (9.5 mm) outer diameter
Installation
• Never cut or shorten the heating cable
• For outdoor applications only
• The heating cable must be completely embedded in concrete, asphalt, or stone dust under paving
• Minimum installation temperature -5 °C (23 °F)
• Maximum long-term exposure temperature 105 °C (221 °F)
• Maximum exposure temperature for 10 minutes 220 °C (428 °F)
For more information, Click Here - PDF
Please contact us for any additional options seen on specification sheet.
Application
• Residential driveway, sidewalk, access ramp, underground parking ramp, boarding platforms for animals
Construction
• Series heating cable set, twin conductor type
• Heating cable held as a mat at regular 3" (76 mm) spacing with flexible strips
• Fluoropolymer/XLPE resistance wire insulation 0.019" (0.5 mm) thick
• Copper shielding (0.823 sq. mm), serves as ground
• Polyolefin (EPR) outer sheath insulation 0.08" (2 mm) thick
Dimensions
• 24" (610 mm) wide
Cold lead
• 50' (15 m) long
• 12 AWG or 14 AWG (according to maximum allowable load)
• PVC outer sheath insulation 0.03" (0.76 mm) thick
• 3/8" (9.5 mm) outer diameter
Installation
• Never cut or shorten the heating cable
• For outdoor applications only
• The heating cable must be completely embedded in concrete, asphalt, or stone dust under paving
• Minimum installation temperature -5 °C (23 °F)
• Maximum long-term exposure temperature 105 °C (221 °F)
• Maximum exposure temperature for 10 minutes 220 °C (428 °F)
For more information, Click Here - PDF