Features
• Magnetic, phase cut dimmable
• Outdoor black powder coated steel enclosure
• Double circuit: 2 x 12VDC
• Total wattage: 600W max
• Input voltage: 2 x 120V 60Hz
Transformer
• Dimmable with compatible MLV, ELV, and CL dimmers
• Temperature class B(130°C)
• Two section bobbin completely separated primary and secondary windings
• Input leads are 18AWG 600V
• Output leads are 12AWG 300V
• Leads max. operational temperature is 105°C
• Thermal manually reset primary breaker 5A
• Magnetic manually reset secondary breaker 25A per circuit
Housing
• 600W transformer is encapsulated in the enclosure
• Enclosure is black powder coated steel, NEMA 3R rated
• Wiring compartment has 12 knockouts sizes for 3/8 inch screw cable connectors
• Enclosure temperature does not exceed 75°C at 45°C ambient and fully loaded
• Dimensions (inch): H = 10.29, W = 6.79, D = 4.68
Electrical Parameters
• Input voltage: 2 x 120V 60Hz
• Max. input current at full load: 6A
• Output voltage without load: 12.5VDC
• Output voltage fully loaded: 11.5VDC
• Max. total wattage: 600W
• Max. per circuit: 300W
• Max. output current: 25A per circuit
• Efficiency: 93%
For more information, Click Here - PDF
For installation instructions, Click Here - PDF
Please contact us for any additional options seen on specification sheet.